You're seeing this message (and this very primitive page) because your browser does not support current web standards. As such, the information in this website is available to you, but with no bells and whistles. To view this website as it was originally intended, please upgrade your browser to the latest version available.


Blade Appearance and Symptoms Probable Causes Remedy
Uneven wear - frequent blade change
  1. A. Poor roll surface.
  2. B. Damaged or dirty blade holder.
  3. C. Deposits.
  1. A. Use more flexible blade.
  2. B. Clean, repair or replace holder.
  3. C. Use abrasive blade.
Excessive wear in center of blade or at ends
  1. A. Doctor not machined to match roll crown.
  2. B. Old doctor sagging into/away from roll.
  1. A. Refit and shim holder to doctor back as necessary. (Return new doctor for replaning if mismatch is excessive.)
  2. B. Replace old, sagging doctor.
Excessive wear on one end Doctor misaligned — not parallel to roll axis. Shim, or move bearings and brackets as necessary to align doctor parallel to axis of roll
Even wear but rough edge
  1. A. Deposits on roll.
  2. B. Excessive pressure on blade.
  3. C. Blade material too hard.
  1. A. Use abrasive blade as required.
  2. B. Reduce pressure.
  3. C. Use softer blade.
Excessive wear in sheet run Deposits left on roll by sheet.
  1. A. Use abrasive blade as required.
  2. B. Trim blade edges frequently.
  3. C. Use end slotted blades to prevent build-up of excessive pressure on roll ends.
Excessive wear outside sheet Sheet lubricates roll Slot blade ends to relieve pressure.
Localized pitting Blade attacked by (1) Electrostatic discharge, (2) Electrolysis, (3) Heat Insulate doctor from machine frame or use non-metallic blade.
Blade develops feathered edge
  1. A. Blade material too soft.
  2. B. Excessive pressure.
  3. C. Blade angle too flat.
  1. A. Use harder blade.
  2. B. Reduce pressure.
  3. C. Move bearings or brackets to increase angle. Check for correct angle with gauge.
Hooks on blade outside roll surface Blade overhangs roll
  1. A. Not centered.
  2. B. Too long.
  3. C. Not oscillating properly.
  1. A. Center blade.
  2. B. Trim Length.
  3. C. Adjust oscillation stroke.
Dent in blade edge Blade caught scab on roll at start-up. (Most common on old dryers.) Change blade and remove scab.
Increasing pressure incrases deflection Blade pressure changed after initial wear-in; (opens blade tip to trap particles and lift blade — may cause wrap. Reduce blade pressure or change blade.

Note: Always inspect worn blades for clues to any problems.

Essco has earned its reputation as the quality leader in doctoring by consistently providing our customers with superior service, value, and innovative, high quality products. In addition Essco manufactures coater blades, doctors, blade holders, The Edge™, electronic doctor gauge, oscillators, foils, suction boxes/covers, felt suction pipes/covers, and caliper controls. Contact Essco today for engineering recommendations and details, to schedule a visit from your Essco Sales Representative, or to request a quotation.